Transformers and Inductors, 50 VA to over 1 MW
7.2 MW, 450 uS Pulse Transformer
Utilizes water cooling on primary windings
For use in an industrial linear accelerator
Specifications

Operating Conditions
Pulse Width .....................
Pulse Repetition Rate ....
Primary Voltage ..............
Primary Current ...............
Secondary Voltage ........
Secondary Current .........
Average Power ...............
Reset Current ..................

Mechanical
Length ..............................
Depth ................................
Height ...............................
Weight ..............................

450 uS
60 PPS Max.
8.5 kV Peak
850 A Peak
34 kV Peak
215 A Peak
250 kW
0.5 A Min through
secondary winding

34.50”
33.00”
54.50”
1,400 Lbs.

Features
NEMA 1 enclosure- custom paint
Water-cooled primary windings
1

963 Ames Avenue Milpitas, CA 95035

tel(408)263-8444

fax(408)263-8448
© 2004-2005